HTRF Cover Hose
|
The HTRF Cover
hose was developed to combat the
primary cause of water-cooled cable failure: wear through of the outer
cover. Often a hose wears through due to abrasion on the welding
equipment
or production components.
WATTEREDGE-UNIFLEX has developed a super high abrasion compound which can outlast other materials 40 to 1 against failure due to abrasion. This compound is integrated into the HTRF cover hose, which is available for all kickless cables and also for water cooled jumpers up to 600 MCM in size. Also available is a high abrasion thin wall sleeve, which can be mounted over the standard kickless cable hose. |
DC Cable / 500 and 650 MCM
|
Opposed
polarity cables for high amperage, direct
current applications.
These heavily reinforced, two conductor water cooled cables are primarily used on heavy duty spot welding stations for joining aluminum panels. This cable is designed to operate at welding currents typically in the range of 45,000 to 55,000 amps D.C. Several design features maximize cable life and are exclusive to these WATTEREDGE-UNIFLEX cables:
|
How to install water cooled
cables
Water cooled jumpers should always be installed with a
bend radii ranging
from 90° to 180°. See the chart below for the minimum recommended
radii.
|
|||||||||||||||||
|
|
||||||||||||||||
| Step 1
Lay one side of a straight edge across the graph at the six cycles of current "one time" point (the left hand vertical scale of the conversion factor chart). Step 2
Step 3
Step 4
Now proceed to the Water Cooled Jumper Selection Chart to read complete the selection. |
|
Step 5
Line up your straight edge on the 19,200 continuous duty amp mark,
and find the intersection with your desired length line (from below, we
want 60 inches).
Step 6
Any cable whose line is above this point may be safely used, since
the load it would carry will be within its thermal capacity. In our
case
the 1000 MCM cable would be the best match, and will not exceed the
design
specifications of the jumper cable.

|
|