The T. J. Snow Company
T. J. Snow  >  Supplies  >  Miyachi  >  Fine Spot Equipment Chart
 

Miyachi Fine Spot Welder Specifications Guide --

Power Supply - Transformer Chart

 
Model
Number
Transformer Maximum
Capacity
Current Range* Control Types Schedules
Availible
Time Monitor
Capability
Power
Source
Interface
AC
ME - 10F - GC
-HC
-DC
(Versions)
MT-510A 5.6 KVA @ 1.5% duty cycle 0.2 - 1.6KA (RMS) Primary Voltage Compensation 1 1/2 to 99 cycles No 220 VAC No
MT-520A 18.5 KVA @ 1.5% duty cycle 0.5 - 3.7KA (RMS)
AC
ME-35A
MT-510A 18.5 KVA @ 1.5% duty cycle 0.2 - 1.6KA (RMS) Prim. Constant Current, Secondary Constant Current,
Primary Voltage Compensation
7 0 to 99 cycles
or 1/2 cycle each
Yes 220 VAC I/O Port
WELCARD
MT-520A 18.5 KVA @ 1.5% duty cycle 0.4 - 3.7KA (RMS)
MT-530A 35 KVA @ 1.5% duty cycle 0.7 - 7.7KA (RMS)
Capacitor Discharge
MC-80B
MT-80D 21 Welds/min @ 160 Watt-sec. 1.5 - 6.7KA (Peak) -- 2 No Setting No 120 VAC I/O Port
Capacitor Discharge
MC-160B
MT-160D 20 Welds/min @ 160 Watt-sec. 1.5 - 7KA (Peak) -- 2 No Setting No 120 VAC I/O Port
Transistor
MD-1000E
-- 3 KVA @ 0.3% duty cycle 200 - 1,000A (Peak) Constant Power 1 0.5-4.99 MS Yes 120/220 VAC Monitor Output & Analog Output
Transistor
MD-1500E
-- 4.5 KVA @ 0.3% duty cycle 300 - 1,500A (Peak) Constant Power 1 0.5-4.99 MS Yes 120/220 VAC Monitor Output & Analog Output
Frequency
Inverter
IP-215A
IT-500A 12.5 KVA @ 8% duty cycle 0.2 - 2KA (RMS) Constant Current, Constant Voltage, Constant Power 7 0-99 MS
Weld 1 
& Weld 2
Yes 220 VAC
3-phase
30 Amp
I/O Port
WELCARD
RS-485
(Optional)
IT-501A 12.2 KVA @ 7% duty cycle 0.2 - 1.5KA (RMS)
Frequency
Inverter
IP-217A
IT-500A 12.5 KVA @ 8% duty cycle 0.5 - 2KA (RMS) Constant Current, Constant Voltage, Constant Power 7 0-99 MS
Weld 1 
& Weld 2
Yes 220 VAC
3-phase
50 Amp
I/O Port
WELCARD
RS-485
(Optional)
IT-501A 12.2 KVA @ 7% duty cycle 0.4 - 1.5KA (RMS)
IT-510A 26 KVA @ 6% duty cycle 0.4 - 4KA (RMS)
IT-511A 25 KVA @ 5% duty cycle 0.4 - 3KA (RMS)
IT-512A 48 KVA @ 5% duty cycle 0.4 - 4KA (RMS)
Frequency
Inverter
IS-217A
IT-510A 26 KVA @ 5% duty cycle 0.4-4 KA
(RMS)
Constant Current, Constant Power, Fixed Pulse, Primary Current, Limit, Primary Current, Seam Weld (Option) 15 0-600 MS
Weld 1
& Weld 2
0-36 Cycles
Weld 1
& Weld 2
Yes 220 VAC
3-phase
50 Amp
I/O Port
MA-201C
Program Unit
IT-511A 25 KVA @ 5% duty cycle 0.4-3 KA
(RMS)
IT-512A 48 KVA @ 5% duty cycle 0.4-4 KA
(RMS)
*The Current Range is dependent on the secondary current.


Fine Spot / Micro Welder Menu:
Real World Applications | Heads | Accessories and Other Miyachi Products
Power Supplies and Transformers:
Overall Table | Frequency Inverter | AC | Transistor | Capacitor Discharge
Welding Supplies | Return to T. J. Snow

Contact
Information:
120 Nowlin Ln
P. O. Box 22847
Chattanooga, TN 37422
(423) 894-6234
1-800-NOW-SNOW
FAX (423) 892-3889
ORDER FAX (423) 490-2417
=Click to Email= welders@tjsnow.com