Weldtouch Secondary Constant Current AC Welding  Controls and Contactors

 

 
 
 
 
 

Miyachi SC-210 Contactor

CY-210B
SC-210 Contactor
CT-110B

Using Secondary Constant Current to gain control of your resistance welding process can result in less down time, reduced scrap, and higher production efficiencies.

Miyachi's Weltouch(tm) AC weld controls with secondary constant current feedback examine each half cycle of the actual weld current flow and compensate for the changes in secondary current during welding. Standard built-in current and conduction degree monitors allow for simultaneous viewing of both programmed and actual weld conditions. Miyachi's secondary constant current feedback combined with our built-in weld monitors can provide a higher degree of accuracy, confidence, and control in AC resistance welding. The Weldtouch SC-210 and CY-110B offer a variety of SCR sizes and optional contactor accessories. The Weldtouch CY-210b and CT-110B are easily adaptable to most existing contractor cabinets.

The following graphs show the difference a Constant Current Control can make:
 

Trend Lines -- CY-210B & CT-110B
This is what your primary line voltage does when presented with a load. Primary Line Voltage
See the corresponding drop in secondary weld current. Secondary Welding Current -- Open Loop
Now see how the constant current control keeps the secondary current from dropping off.  Secondary Welding Current -- With constant current feedback (closed loop)

Constant Current Feedback Theory
Using a toroidal coil, the current wave form is reconstructed from the output signal. It is then transformed into an RMS effective value using the following formula:
Constant Current Feedback Theory
The control then compares this effective value with the set current value. The weld current is corrected with every half cycle through phase conversion and trigger pulse oscillation. The result is smooth, consistent secondary welding current delivered at the weld regardless of the line voltage fluctuations.



CT-110B
CT-110B Constant Current Weld Control (right)
 

1. Schedule number: Up to 15 schedules can be stored in memory for instant recall.
2. Three impulse weld time: Provides weld time flexibility for a wide variety of welding applications.
3. Weld Current: Weld 1, 2, 3 can be set and displayed.
4. Current and Conduction degree monitor: Sets the High and Low current limit (1-->99%) and monitors current fluctuation and conduction degrees.
5. Valve and Mode Select: Step-up / Counters / Turn Ratio, +/-% Current Window
6. Caution and Error Indicators: No current, Overtemp, SCR Short, Current Limit, No weld, and Step End.
7. Emergency Stop
8. Reset
 
 
 

CY-210B Constant Current Weld Control (below)Miyachi Weltouch CY-210B

SC-210 Contactor (below)
Miyachi SC-210 Contactor
 
  SC-210 SC-210CB
SCR Options 300A Air Cooled
1200A Water Cooled
1700A Water Cooled
3200A Water Cooled
Circuit Breaker Options N/A 225A
400A
Operator Control Options Emergency Stop
Key Switch / Program Lock
Control Power On / Off
Main Power Indicator
Retraction Valve 115V or 24V
Primary Current Sensor
Dimensions:
(includes 1" (25.4 mm) 
clearance for push buttons)
24 x 20 x 10 in
(610 x 508 x 254 mm)
30 x 36 x 12 in
(762 x 914 x 305 mm)

 
Specifications
Model CY-210B CT-110B
Control Power
Weld Power
120 VAC, +/- 20%, 50/60 Hz.
220 VAC / 440 VAC +10%, -25%, 50/60Hz autoselect
Weld Current
Control Systems:
Secondary Feedback
Primary Feedback
Primary Voltage Compensation
Control Speed: Secondary Constant Current: 1/2 Cycle
Primary Constant Current: 1/2 Cycle
Primary Voltage: 1 Cycle
Current Range: 1 kA to 80 kA
(Maximum: 5 kA to 80 kA)
Timer Settings:
   Squeeze
   Preheat
   Cool 1
   Upslope
   Weld 1
   Cool 2
   Weld 2
   Down Slope
   Hold
   Off
   Pulsation
15 Schedules
00-99 cycles
0-9 cycles
0-9 cycles
0-9 cycles
00-99 cycles
00-99 cycles
00-99 cycles
00-99 cycles
00-99 cycles
00-99 cycles
1-9 times
15 Schedules
00-99 cycles
00-99 cycles
00-99 cycles
00-99 cycles
00-99 cycles
00-99 cycles
00-99 cycles
00-99 cycles
00-99 cycles
00-99 cycles
1-9 times
Valve Outputs: 2 schedules
Output is 100 VAC, max 1 amp
or 24 VDC
by Triac control
1 schedule
Output is 100 VAC, max 1 amp
or 24 VDC
by Triac control
Current Steppers: 2 schedules
9 step counter -- 0-9,999
Step Up rate: -50 to 99% 
(1% increments)
1 schedule
9 step counter -- 0-9,999
Step Up rate: -50 to 99% 
(1% increments)
Current Monitor: 15 schedules
High Limit: 1 to 49%
Low Limit: -1 to -49%
Set at 0 for no monitoring
Conduction
Degree Monitor:
1 to 180 degrees, 15 schedules
Set at 0 for no monitoring
Fault List: A) Over Temp
B) SCR short
C) No current or Toroidal coil error
D) No Weld
E) Self Diagnostic Error
F) Start input Error (parity check error)
Dimensions:
H x W x D
14 x 4.7 x 9.8 in
(356 x 119 x 249 mm)
4.8 x 14 x 9.8 in
(112 x 356 x 249 mm)
Weight: 9.9 lbs
(4.5 kg)
Toroidal Coil: MB-400L (I.D.: 5")

For more information, or help selecting or pricing a controls system, feel free to contact T. J. Snow. You might also be interested in:


Weld Checker Chart | Other Miyachi Products and Accessories
Welding Supplies | Return to T. J. Snow

Contact
Information:
120 Nowlin Ln
P. O. Box 22847
Chattanooga, TN 37422
(423) 894-6234
1-800-NOW-SNOW
FAX (423) 892-3889
ORDER FAX (423) 490-2417
=Click to Email= welders@tjsnow.com