Stock Number: 5531
30 KVA
PRESS SPOT -- PEER
 
Mfg. Model No: P25
Voltage: 480 Volts, Single Phase
Service: 60 Amp, 60 Hz.
Throat Depth: 20"
Air Type: Standard Dual Acting
Cylinder Diameter: 4"
Weld Force: 1000 lbs. @ 80 PSI
Initiation: Foot Switch



 

Snow Stock # 5531, used press welder
Alternate Photo of  #5531


Stock Number: 6043
30 KVA
PRESS SPOT -- BANNER
 
Model:                          SM1SPQ030A12
Voltage: 220 Volts, Single Phase
Service: 100 Amp, 60 Hz.
Secondary Volts: 2.7 - 5.2
Throat Depth: 12"
Air Type: Standard Dual Acting
Cylinder Diameter: 4"
Weld Force: 1000 lbs. @ 80 PSI
Tap Switch: 5-Step
Initiation: Foot Switch



Stock #6043, Photo Pending
Alternate Photo of  #6043


 

Stock Number: 5374
50 KVA
PRESS SPOT -- PRECISION
 
Mfg. Model No: AVA-1
Voltage: 220 Volts, Single Phase, 60 Hz.
Service: 200 Amp, 60 Hz.
Throat Depth: 20"
Secondary Volts: 5.5 - 11.0
Air Type: Standard Dual Acting
Cylinder Diameter: 5"
Weld Force: 1,570 lbs. @ 80 PSI
Initiation: Foot Switch



Snow Stock # 5374, used press welder
Alternate Photo of  #5374


Stock Number: 5535
50 KVA
PRESS SPOT -- DENGENSHA
 
Mfg. Model No: Model ND-50-410
Voltage: 460 Volts, Single Phase, 60 Hz.
Service: 100 Amp, 60 Hz.
Throat Depth: 18"
Secondary Volts: 8.1 - 12.4
Secondary Amps: 18,000
Air Type: Standard Dual Acting
Cylinder Diameter: 6"
Weld Force: 2,260 lbs. @ 80 PSI
Initiation: Foot Switch



Snow Stock # 5535, used press welder
Alternate Photo of  #5535


Stock Number: 5536
50 KVA
PRESS SPOT -- DENGENSHA
 
Mfg. Model No: ND-50-410
Voltage: 460 Volts, Single Phase, 60 Hz.
Service: 100 Amp, 60 Hz.
Throat Depth: 18"
Secondary Volts: 8.1 - 12.4
Secondary Amps: 18,000
Air Type: Standard Dual Acting
Cylinder Diameter: 6"
Weld Force: 2,260 lbs. @ 80 PSI
Initiation: Foot Switch



Snow Stock # 5536
Alternate Photo of  #5536


Stock Number: 5537
50 KVA
PRESS SPOT -- DENGENSHA
 
Mfg. Model No: ND-50-410
Voltage: 460 Volts, Single Phase, 60 Hz.
Service: 100 Amp, 60 Hz.
Throat Depth: 18"
Secondary Volts: 8.1 - 12.4
Secondary Amps: 18,000
Air Type: Standard Dual Acting
Cylinder Diameter: 6"
Weld Force: 2,260 lbs. @80 PSI
Initiation: Foot Switch



Snow Stock # 5537
Alternate Photo of  #5537


Stock Number: 5516
50 KVA
PRESS SPOT -- RWC
 
Mfg. Model No: C.PRESS
Voltage: 440 Volts, Single Phase, 60 Hz.
Throat Depth: 17"
Secondary Volts: 1.85 - 7.33
Secondary Amps: 25,500
Air Type: Standard Dual Acting
Cylinder Diameter: 4.5"
Weld Force: 1,272 lbs. @ 80 PSI
Initiation: Foot Switch
   



Snow Stock # 5516
Alternate Photo of  #5516


Stock Number: 5477
50 KVA
PRESS SPOT -- ACME
 
Mfg. Model No. PT1S-18-50
Voltage: 460 Volts, Single Phase, 60 Hz.
Throat Depth: 20"
Air Type: Standard Dual Acting
Cylinder Diameter: 4"
Weld Force: 1,000 lbs. @ 80 PSI
Initiation: Foot Switch
   
   
   



Stock #5477
Alternate Photo of  #5477


Stock Number: 6118
50 KVA
PRESS SPOT -- TAYLOR WINFIELD
 
Mfg. Model No. ENC-12-50
Voltage: 440 Volts, Single Phase, 60 Hz.
Throat Depth: 18"
Arm Diameter: 2.25" Upper / 3" Lower
Air Type: Adjustable/Retractable
Cylinder Diameter: 5"
Weld Force: 1,570 lbs. @ 80 PSI
Tap Switch: 8-Step
Initiation: Foot Switch



Stock #6118
Alternate Photo of  #6118


Stock Number: 5941
50 KVA
PRESS SPOT -- SCIAKY
 
Mfg. Model No: EPK.1-15-50-12
Voltage: 220 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Throat Depth: 24"
Air Type: Standard Dual Acting
Cylinder Diameter: 4"
Weld Force: 1,000 lbs. @ 80 PSI
Initiation: Foot Switch
Weld Control Entron Model EN1000 w/CB



 

Snow Stock # 5941
Alternate Photo of  #5941


Stock Number: 6092
50 KVA
PRESS SPOT -- PROGRESSIVE
 
Mfg. Model No: 640ES1
Voltage: 220 Volts, Single Phase
Service: 100 Amp, 60 Hz.
Throat Depth: 24"
Secondary Volts: 3.8 - 5.6
Air Type: Standard Dual Acting
Cylinder Diameter: 4"
Weld Force: 1,000 lbs. @ 80 PSI
Initiation: Foot Switch
Weld Control Intertron 105



 

Snow Stock # 6092
Alternate Photo of  #5941


Stock Number: 4054
75 KVA
PRESS SPOT -- FEDERAL
 
Voltage: 220 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Throat Depth: 12"
Air Type: Standard Dual Acting
Cylinder Diameter: 3"
Weld Force: 770 lbs. @ 80 PSI
Initiation: Foot Switch



Snow Stock # 4054
Alternate Photo of #4054


Stock Number: 4059
75 KVA
PRESS SPOT -- FRANK BRANDT
 
Voltage: 550 Volts, Single Phase
Throat Depth: 24"
Air Type: Adjustable Stroke
Cylinder Diameter: 4.0"
Weld Force: 1,000 lbs. @ 80 PSI
Initiation: Foot Switch



Snow Stock # 4059
Alternate Photo #4059


Stock Number: 5681
75 KVA
PRESS SPOT -- FEDERAL
 
Model:                          PA-1-12
Voltage: 440 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Throat Depth: 12"
Secondary Volts: 4.4 - 7.6
Secondary Amps: 47,000
Air Type: Standard Dual Acting
Cylinder Diameter: 5"
Weld Force: 1,570 lbs. @ 80 PSI
Tap Switch 8-Step
Arm Dimensions: Upper:  2.0" x 2.5" Square
  Lower:  2.0" x 2.5" Square
Initiation: Foot Switch



Snow Stock # 5681
Alternate Photo #5681


Stock Number: 6085
75 KVA
PRESS SPOT -- LORS
 
Model:                          175AP
Voltage: 440 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Throat Depth: 36"
Air Type: Standard Dual Acting
Cylinder Diameter: 5"
Weld Force: 1,570 lbs. @ 80 PSI
Initiation: Foot Switch
Weld Control Entron EN300-600C



 

Snow Stock #6085
Alternate Photo of  #6085


Stock Number: 5952
75 KVA
PRESS SPOT -- ACME
 
Model:                          PT1S-24-75
Voltage: 460 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Throat Depth: 24"
Secondary Volts; 2.55 - 10.45
Secondary Amps: 24,500
Air Type: Adjustable/Retractable
Cylinder Diameter: 6"
Weld Force: 2,260 lbs. @ 80 PSI
Tap Switch 8-Step
Initiation: Foot Switch
Weld Control Entron EN300-600C



 

Snow Stock #5952
Alternate Photo of  #5952


Stock Number: 5183
75 KVA
PRESS SPOT -- THOMPSON
 
Voltage: 440 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Throat Depth: 18"
Secondary Volts; 4.5 - 12.9
Air Type: Adjustable Stroke
Cylinder Diameter: 6"
Weld Force: 2,260 lbs. @ 80 PSI
Initiation: Foot Switch



 

Snow Stock #5183
Alternate Photo of  #5183


Stock Number: 5782
80 KVA 
High Speed Stitch Welder -- ACRO
 
Voltage: 460 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Throat Depth: 15"
Secondary Volts: 4.0 - 9..17
Secondary Amps: 31,600
Tap Switch: 8-Step
Weld Control: Used Medweld 4000S
  with Toggle Switch for 
  single spot or stitch welding
   
Dimensions: in current configuration
  as shown in photo
  40" wide
  42" deep
  67" high
  43" work height



 

Snow Stock # 5782
Representative Photo


Stock Number: 5263
80 KVA Fixture Type Transformer
PRESS SPOT -- FRANK BRANDT
 
Voltage: 460 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Throat Depth: 24"
Air Type: Standard Dual Acting
Cylinder Diameter: 4"
Weld Force: 1,000 lbs. @ 80 PSI
Initiation: Foot Switch
Weld Control: Used Entron EN-200



Snow Stock # 5263
Alternate Photo of  #5263


Stock Number: 5080
75 KVA
PRESS SPOT -- FEDERAL
 
Voltage: 440 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Throat Depth: 24"
Air Type: Standard Dual Acting
Cylinder Diameter: 4"
Weld Force: 1,000 lbs. @ 80 PSI
Initiation: Foot Switch
Weld Control: removed



Snow Stock # 5080
Alternate Photo of  #5080


Stock Number: 6027
75 KVA
PRESS SPOT -- TAYLOR WINFIELD
 
Voltage: 440 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Throat Depth: 18"
Air Type Adjustable/Retractable
Cylinder Diameter: 5"
Weld Force: 1,570 lbs. @ 80 PSI
Tap Switch: 5-Step Hi/Low



Snow Stock # 6027
Alternate Photo of  #6027


Stock Number: 5706
100 KVA
PRESS SPOT -- TAYLOR WINFIELD
 
Voltage: 440 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Throat Depth: 24"
Air Type: Adjustable/Retractable
Cylinder Diameter: 5"
Weld Force: 1,530 lbs. @ 80 PSI
Tap Switch: 8-Step
Initiation: Foot Switch



 

Snow Stock # 5706
Click to see a Representative Photo of  an
exact model after complete Remanufacture




Stock Number: 6040
100 KVA
PRESS SPOT -- ACME
 
Model: PT1S-28-100
Voltage: 460 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Secondary Voltage: 6.11 - 12.22
Secondary Amps: 28,000
Throat Depth: 28"
Air Type: Adjustable Stroke
Cylinder Diameter: 6"
Weld Force: 2,260 lbs. @ 80 PSI
Tap Switch 8-Step
Initiation: Foot Switch
**Remanufactured** Matching the two machines below.



 

Snow Stock #6040
Alternate Photo of  #6040


Stock Number: 6041
100 KVA
PRESS SPOT -- ACME
 
Model: PT1S-28-100
Voltage: 460 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Secondary Amps: 37,000
Throat Depth: 28"
Air Type: Adjustable Stroke
Cylinder Diameter: 6"
Weld Force: 2,260 lbs. @ 80 PSI
Tap Switch 8-Step
Initiation: Foot Switch



 

Snow Stock # 6041
Alternate Photo of  #6041


Stock Number: 6042
100 KVA
PRESS SPOT -- ACME
 
Model: PT1S-28-100
Voltage: 460 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Secondary Volts: 6.11 - 12.22
Secondary Amps: 28,000
Throat Depth: 28"
Air Type: Adjustable Stroke
Cylinder Diameter: 6"
Weld Force: 2,260 lbs. @ 80 PSI
Tap Switch 8-Step
Initiation: Foot Switch



 

Snow Stock # 6042
Alternate Photo of  #6042


Stock Number: 6129
100 KVA
PRESS SPOT -- McKAY FEDERAL
 
Model: PA-1-12
Voltage: 460 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Secondary Volts: 3.61 - 10.0
Secondary Amps: 65,000
Throat Depth: 18" w/ Platen Mounted Arms
Air Type: Standard Dual Acting
Cylinder Diameter: 6"
Weld Force: 2,260 lbs. @ 80 PSI
Tap Switch 8-Step
Initiation: Foot Switch



 

Snow Stock # 6129
Alternate Photo of  #6129


Stock Number: 5948
100 KVA
PRESS SPOT -- SCIAKY
 
Model: EPK-2-30-100-2
Voltage: 480 Volts, Single Phase
Service: 200 Amp, 60 Hz.
Secondary Volts: 3.55 - 8.5
Secondary Amps: 46,000
Throat Depth: 20"
Air Type: Adjustable Stroke
Cylinder Diameter: 7"
Weld Force: 3,070 lbs. @ 80 PSI
Tap Switch 8-Step
Initiation: Foot Switch



 

Snow Stock # 5948
Alternate Photo of  #5948


Stock Number: 5906
150 KVA
PRESS SPOT -- PEER
 
Model:                          P-100
Voltage: 480 Volts, Single Phase
Service: 400 Amp, 60 Hz.
Secondary Volts: 3.7 - 10.4
Throat Depth: 18"
Air Type: Adjustable/Retractable
Cylinder Diameter: 8"
Weld Force: 4,020 lbs. @ 80 PSI
Tap Switch: 8-Step, Hi/Low
Initiation: Footswitch
   



 

Snow Stock # 5906
Alternate Photo of  #5906


Stock Number: 6076
150 KVA
PRESS SPOT -- LORS
 
Model:                          1150AP-1
Voltage: 460 Volts, Single Phase
Service: 400 Amp, 60 Hz.
Secondary Volts: 6.4 - 11.0
Throat Depth: 30"
Air Type: Standard Dual Acting
Cylinder Diameter: 6"
Weld Force: 2,260 lbs. @ 80 PSI
Initiation: Footswitch
   



 

Snow Stock # 6076
Alternate Photo of  #6076



Return to Index

Search Again

Contact
Information:
120 Nowlin Lane (37421)
P. O. Box 22847
Chattanooga, TN 37422
(423) 894-6234
1-800-NOW-SNOW
FAX (423) 892-3889
ORDER FAX (423) 490-2417
=Click to Email= welders@tjsnow.com

   Search this site       powered by FreeFind
[Service Department] [Welder Supplies] [Seminars] [Outside Sales]
[Machinery and Robotics] [Custom Design Machinery] [Remanufacturing]
[Standard Machines] [Slim Line Machines] [Transformer Department]
[Visit Us] [NEW at TJS] [Site Map] [Machine Shop